Valve salt spray test

As we all know that the valve body like carbon steel (WCB, WCC, LCB, LF2, A105), stainless steel (SS304, SS316, F304L, F316L), hastelloy (Alloy 20) etc., or even in the trim material always use metallic materials.


Most of the corrosion of metallic materials occurs in the atmosphere, which contains corrosive components and corrosive factors such as oxygen, humidity, temperature changes and pollutants. Salt spray corrosion is a common and most destructive atmospheric corrosion.


The salt spray test is divided into two categories, one is the natural environmental exposure test, and the other is the artificial accelerated simulated salt spray environmental test. The artificial simulated salt spray environment test uses a test equipment with a certain volume space, the salt spray test chamber, to artificially use the salt spray environment in the volume space to assess the salt spray corrosion resistance quality of the product.



Compared with the natural environment, the salt concentration of the chloride in the salt spray environment canbe several times or dozens of times that of the salt spray content of the general natural environment, so that the corrosion rate is greatly improved, and the product is subjected to a salt spray test to obtain a result. The time is also greatly shortened. If a product sample is tested in a natural exposure environment, it may take 1 year to corrode, and in a simulated salt spray environment, as long as 24 hours, similar results can be obtained.


When Should a Y-Type Filter Be Selected?

Y-type filters are widely utilized across various industrial sectors, including petroleum, chemicals, pharmaceuticals, food processing, water treatment, and more. These filters effectively remove impurities and particulate matter from fluids, safeguarding downstream equipment from contamination and damage while enhancing product quality and production efficiency. Here are some specific scenarios where Y-type filters are ideally suited:

Y Type Strainer

1. Industry Applications:

(1) Chemicals and Petrochemicals: In chemical and petrochemical processes, Y-type filters filter weakly corrosive materials such as water, ammonia, oils, hydrocarbons, etc., to eliminate impurities and solid particles, protecting production equipment and enhancing product quality.

(2) Oil and Petrochemical Industry: Used for filtering liquids like crude oil, fuel oil, and lubricants, ensuring smooth equipment operation and improving product purity and quality.

(3) Pharmaceutical Industry: In pharmaceutical production, Y-type filters purify solutions, liquids, and slurries, removing impurities and particles to guarantee product purity and quality.

(4) Food and Beverage Industry: During food processing and beverage production, Y-type filters filter juices, beer, milk, drinking water, etc., eliminating suspended solids, microorganisms, and other contaminants, ensuring product hygiene and safety.

(5) Microelectronics Industry: In microelectronics manufacturing, Y-type filters filter chemical solvents, cleaning solutions, etc., in the semiconductor industry, ensuring product quality and smooth operation of manufacturing equipment.


2. Filtration Needs:

(1) Equipment Protection: When fluids contain solid particles, these can clog or damage critical equipment like pipes, pumps, nozzles, and instruments. Y-type filters effectively block these particles, protecting equipment from damage.

(2) System Reliability Enhancement: By filtering impurities from fluids, Y-type filters improve overall system reliability and stability, reducing failures and downtime caused by contaminants.


3. Applicable Media:

Y-type filters are suitable for various media, including water, oil, gas, and corrosive substances, making them widely applicable in fluid processing across industries.


4. Selection Considerations:

When selecting a Y-type filter, factors such as flow requirements, filtration accuracy, media properties, and working pressure must be considered to ensure the appropriate model and specifications are chosen. Different Y-type filter models (e.g., GL11W threaded stainless steel Y-type filter, GL41H flanged stainless steel Y-type filter) have distinct characteristics and application scopes, requiring selection based on actual needs.


Y-type filters are appropriate when filtering solid particles from fluids in pipeline systems to protect equipment and enhance system reliability. Selection should also consider specific application scenarios and requirements.

How to Check if Heat Cable is Working

Checking if a heat cable (also called heat tape) is working properly is important to prevent freezing pipes or roof ice dams. Here’s how to verify its functionality:

 

1. Visual Inspection

  • Check for physical damage (cracks, frayed wires, or burnt spots).

  • Look for indicator lights (some heat cables have a small light showing power is on).

2. Touch Test

  • For pipes: Feel along the cable (carefully—it shouldn’t be scalding hot). It should be warm to the touch.

  • For roofs/gutters: Check if ice is melting where the cable is installed (after it’s been on for a while).

3. Use a Non-Contact Voltage Tester (For Plug-In Cables)

  • Turn on the heat cable and hold the tester near the cord or outlet—it should detect voltage if power is flowing.

4. Check with a Multi-meter (For Hardwired or Suspected Faulty Cables)

  • Unplug the cable and set the multi-meter to measure resistance (Ohms Ω).

  • Touch the probes to the prongs of the plug (for plug-in cables) or the ends of the wires.

    • No reading (infinite resistance) = Broken circuit (cable is dead).

    • Low resistance (e.g., 10–100 Ω) = Likely working.

    • Zero resistance (short circuit) = Faulty.

5. Monitor Temperature with an IR Thermometer

  • Point an infrared thermometer at the cable—it should read warmer than the surrounding area.

6. Check the Thermostat (If Applicable)

  • Some heat cables have built-in thermostats that only activate below freezing (~38°F or 3°C). Test by cooling the thermostat (e.g., with an ice pack) to see if the cable warms up.

7. Test the GFCI Outlet (If Plugged In)

  • Press the "Test" button on the GFCI outlet to ensure it trips, then reset it. If it won’t reset, the cable may have a short.

8. Look for Ice Buildup (For Roof/Gutter Cables)

  • If installed on a roof or gutter, the cable should prevent ice dams. If ice persists, the cable may be faulty or poorly installed.

Safety Tips:

  • Always unplug the cable before inspecting for damage.

  • Never wrap heat cables over themselves—this can cause overheating.

  • Replace old or damaged heat cables—they can be a fire hazard.

 

If you’re unsure, consult an electrician or the manufacturer’s guidelines. Let me know if you need help troubleshooting a specific type of heat cable!

 

Roof Heating Cables Temperature Range

Roof heating cables, also known as heat tapes or de-icing cables, typically reach temperatures between 100°F to 150°F (38°C to 65°C) when operating. The exact temperature depends on the type and brand of the cable, as well as the specific application (e.g., for gutters, downspouts, or roof edges).

 

  • Self-regulating heating cables: These adjust their heat output based on the surrounding temperature. They generally stay in the lower range (around 100°F to 120°F) and are safer because they reduce the risk of overheating.

  • Constant-wattage heating cables: These maintain a consistent temperature and can get hotter, often reaching up to 150°F or more. They require careful installation to avoid overheating or damage to roofing materials.

 

The goal of these cables is to melt ice and snow, not to get excessively hot. Proper installation and use are critical to ensure safety and effectiveness. Always follow the manufacturer's guidelines to avoid fire hazards or damage to your roof.

 

Key Considerations for Roof Heating Cables:

  1. Purpose:

    • Roof heating cables are designed to prevent ice dams, which form when snow melts and refreezes at the edge of a roof. Ice dams can cause water to back up under shingles, leading to leaks and damage.

    • They are also used to keep gutters and downspouts clear of ice blockages.

  2. Installation:

    • Cables should be installed in a zigzag pattern along the roof's edge, in gutters, and downspouts to ensure proper coverage.

    • Avoid overlapping the cables, as this can cause overheating.

    • Use clips or brackets designed for roof heating cables to secure them in place without damaging the roof.

  3. Energy Efficiency:

    • Self-regulating cables are more energy-efficient because they adjust their heat output based on temperature. They consume less power when it's warmer and more when it's colder.

    • Constant-wattage cables use a consistent amount of energy regardless of conditions, which can lead to higher energy costs.

  4. Safety:

    • Ensure the cables are rated for outdoor use and are specifically designed for roofs and gutters.

    • Use a ground-fault circuit interrupter outlet to reduce the risk of electrical hazards.

    • Regularly inspect the cables for damage, such as fraying or exposed wires, and replace them if necessary.

  5. Maintenance:

    • Remove debris like leaves and branches from the roof and gutters to prevent blockages and ensure the cables work effectively.

    • Check the cables before winter to ensure they are functioning properly.

  6. Temperature Control:

    • Some systems come with thermostats or sensors to automatically turn the cables on when temperatures drop below freezing and off when they rise above freezing. This helps save energy and prevents unnecessary operation.

  7. Limitations:

    • Heating cables are not a permanent solution to ice dam problems. Addressing underlying issues, such as poor insulation or ventilation in the attic, is essential for long-term prevention.

By using roof heating cables correctly and maintaining them properly, you can effectively manage ice dams and protect your roof from winter damage. Always consult a professional if you're unsure about installation or maintenance. info@jhheat.com

 

 

 

How Shinhoo GPA Series Boiler Pumps Improve Efficiency & Performance

Heating systems are a crucial part of home comfort, but inefficient pumps can lead to higher energy bills, uneven heating, and unnecessary wear and tear. That’s where the Shinhoo GPA Series gas boiler pump comes in—engineered to maximize efficiency, enhance performance, and reduce costs.

Let’s explore how this advanced pump optimizes your heating system while saving energy and money.

 


1. Smart Adaptive Control for Optimal Efficiency

The GPA Series features intelligent gear adjustment, allowing the pump to automatically adapt its operation based on real-time heating demands.

  • Max/PWM Modes: Switch between maximum power and PWM (pulse-width modulation) for precise control.

  • Energy Savings: Adjusts speed to match load conditions, eliminating wasteful energy consumption.

  • Seamless Integration: Works with your boiler to maintain consistent performance without manual intervention.

"Why run at full power when you don’t need to? The GPA Series ensures your pump only uses the energy required."


2. Significant Energy & Cost Savings

One of the biggest advantages of the GPA Series is its outstanding energy efficiency:

  • Low Operating Cost: At 1m³/h flow rate, it consumes only 7.38 EUR in electricity over a 4-month heating season.

  • Long-Term Savings: Households can save up to 9.65 EUR per year—imagine the impact if 2 million homes switched to GPA pumps (293.76 million kWh saved annually!).

This makes it a smart investment for both homeowners and HVAC installers looking for eco-friendly, cost-effective solutions.

 


3. Enhanced Comfort with Real-Time Feedback

Nobody likes cold spots or sudden temperature drops. The GPA Series ensures stable heating and hot water by:

  • Providing real-time data (speed, flow rate, power) to your boiler for precise adjustments.

  • Eliminating temperature fluctuations, keeping your home consistently comfortable.

"A smooth, quiet, and reliable pump means no more surprises—just perfect warmth when you need it."


4. Built to Last: 8 Self-Protection Features

Mechanical failures can be costly. The GPA Series includes advanced protection mechanisms to extend pump life:

✔ Over-voltage & under-voltage protection
✔ Over-current & phase loss detection
✔ Light load & stalled rotor prevention
✔ Over-temperature & overheating safeguards

These features reduce hydraulic shocks, minimize wear, and prevent breakdowns, ensuring longer service life with fewer maintenance issues.

 


5. Compact Design for Easy Installation & Maintenance

  • Space-saving: Measures just 151mm (H) x 93mm (W), fitting seamlessly into tight spaces.

  • User-friendly: Front-mounted control panel for quick adjustments.

  • Simplified servicing: Easy access for maintenance and repairs.

Whether you're a homeowner or an HVAC professional, the GPA Series is designed for hassle-free installation and operation.

 


6. Eco-Friendly Heating for a Sustainable Future

By reducing energy waste, the GPA Series helps:
✅ Lower carbon footprint
✅ Decrease household electricity consumption
✅ Support global energy-saving initiatives

 

With millions of potential installations, the environmental impact is substantial—293.76 million kWh saved per year if adopted widely.


Upgrade to Shinhoo GPA Series for Smarter Heating

 

The GPA Series gas boiler pump isn’t just another component—it’s a high-efficiency, long-lasting solution that cuts costs, improves comfort, and protects the planet.

How To Assemble Mega S Circulation Pump

Water circulation systems demand reliability, energy efficiency, and intelligent protection—and Shinhoo Mega S Circulation Pump delivers on all fronts. Whether for industrial, commercial, or high-performance residential applications, this pump is engineered for durability, precision control, and hassle-free operation.  

 Why Choose  Shinhoo Mega S Pump?  

✅ Built for Safety & Longevity  

✔ A3 Level Explosion-Proof – Safe for hazardous environments  

✔ 10-Year Design Life – Robust construction for extended service  

✔ H-Class Motor Insulation – Withstands extreme temperatures  

✔ High-Performance Bearing Coating – Reduces wear and tear  

 

✅ Energy Efficiency & Quiet Operation  

✔ High Efficiency & Energy Saving – Optimized for reduced power consumption  

✔ Low Noise (≤45dB) – Smooth operation without disruptive sound  

 

✅ Smart Control & Versatility  

✔ 10-Stage Temperature Control – Adjustable thermal management  

✔ 4 Internal Modes + 3 External Control Options – Supports Auto, Constant Speed, Proportional Flow, Constant Pressure, and Temperature Control  

✔ 0-10V, Modbus, 4-20mA, and Temp Control Interfaces – Seamless integration with automation systems  

 

✅ 8 Self-Protection Functions for Maximum Reliability  

The pump automatically detects and responds to:  

- Overvoltage / Undervoltage  

- Overcurrent / Phase Loss  

- Light Load / Locked Rotor  

- Overtemperature / Overheat  

LED indicators provide real-time fault alerts, ensuring quick troubleshooting. 

Key Installation Guidelines  

- Mount horizontally only (±5° tolerance) – *Never install vertically!*  

- Rotate the terminal box 90° if needed for wiring convenience  

- Use included gaskets & O-rings for leak-free sealing  

- Tighten screws diagonally to prevent uneven pressure on flanges  

Critical Pre-Startup Checks  

1. Always ground the pump for electrical safety.  

2. Connect an external power switch for easy control.  

3. Open valves and purge air from pipes before first use.  

4. Avoid overtightening screws to prevent flange damage.  

Control Modes & Gear Adjustment  

- Button 1 – Switches between Auto, Constant Speed, Proportional, Constant Pressure, and Temp Control modes.  

- Button 2 – Adjusts gear settings (default: Gear 3).  

  - In Temperature Control Mode, press to cycle through Gears 4-10.  

Fault Indications (LED Flashing Patterns)  

| Flashes | Protection Mode | Action Required |  

| 1 Flash | Overvoltage | Restart after voltage stabilizes |  

| 2 Flashes | Undervoltage | Restart after voltage recovers |  

| 3 Flashes | Overcurrent | Auto-restart after 8s (5 attempts) |  

| 4 Flashes | Phase Loss | Check wiring, then restart |  

| 5 Flashes | Locked Rotor | Auto-restart after 8s (5 attempts) |  

| 6 Flashes | Light Load | Verify load compatibility |  

| 7 Flashes | Overtemperature | Cool down before restarting |  

Shinhoo Mega S Circulation Pump combines industrial-grade durability, smart automation, and energy-saving efficiency in one compact unit. With multiple control modes, self-diagnostic alerts, and easy installation, it’s the ideal choice for:  

- HVAC systems  

- Industrial cooling circuits  

- Water supply & pressure maintenance  

- Temperature-regulated applications  

 Upgrade to the Mega S Pump today and experience unmatched reliability!  

 

 

Instant Hot Water at Your Fingertips Meet Shinhoo SPA15-12E Instant Hot Water Pump

Tired of waiting for hot water every time you turn on the faucet? Say hello to Shinhoo SPA15-12E Instant Hot Water Pump, the ultimate solution for instant hot water and a more comfortable, efficient lifestyle.

Hot Water Instantly

With Shinhoo SPA15-12E, the moment you turn on the faucet, hot water flows instantly. No more waiting for the water to heat up, whether it’s for your morning shower, washing dishes, or any other daily task. This circulation pump ensures that hot water is always ready when you need it, delivering unparalleled convenience and comfort.

Intelligent Constant Temperature

Say goodbye to fluctuating water temperatures! Shinhoo SPA15-12E features intelligent constant temperature control, ensuring that the water stays at your desired temperature throughout use. Whether it’s a relaxing bath or a quick hand wash, you’ll enjoy a consistent and comfortable experience every time.

Energy-Saving and Efficient

Designed with energy efficiency in mind, Shinhoo SPA15-12E minimizes energy waste while delivering top-notch performance. Its advanced technology ensures that you get hot water quickly without excessive energy consumption, making it an eco-friendly and cost-effective choice for your home or business.

Comfort Without Waiting

Why wait for hot water when you can have it instantly? Shinhoo SPA15-12E transforms your daily routine by eliminating the frustrating delays of traditional water heating systems. Enjoy the luxury of instant hot water and make every moment at home more comfortable and convenient.

Perfect for Any Setting

Whether it’s for residential use or commercial applications, Shinhoo SPA15-12E is designed to meet your needs. Its compact design, reliable performance, and user-friendly features make it the ideal choice for anyone looking to upgrade their hot water system.

Upgrade Your Lifestyle Shinhoo SPA15-12E

Shinhoo SPA15-12E Instant Hot Water Pump is more than just a device—it’s a lifestyle upgrade. With instant hot water, intelligent temperature control, and energy-saving efficiency, it brings comfort and convenience to every corner of your life.

Don’t wait any longer for hot water. Choose Shinhoo SPA15-12E and experience the future of instant, comfortable, and efficient living today!

Is It Worth Getting A Heat Pump?

Yes. Heat pumps are a great way to save money on energy costs. They are also more efficient than traditional heating systems, so they can help reduce your carbon footprint. Heat pumps can also provide both cooling and heating in one unit, making them a great all-in-one solution for your home.
GPA II CV&AUTO series motor pump has the permanent magnet motor and the different pressure controller, which can continuously adjust pump performance to meet actual requirements of the system.  It is mainly applied to home heating and water circulation in domestic hot water system.
The best system met GPA Series circulator pump,following:
·the constant and variable flow heat system
·the heat system of variable flow heat system
·the air-conditioning system
·the industrial circulation system

·the home heating and living water system

GPA II CV&AUTO series motor pump

Shinhoo GPA-H Pump Will Be Unveiled On The 133nd Canton Fair will open on April 15

Guangzhou, a commercial capital over thousand years
All merchants draw together like clouds
The 133nd Canton Fair will open on April 15

Shinhoo GPA-H pump will be unveiled

We sincerely invite purchasing representatives to attend the fair
and explore more possibilities of pumps together with us

Welcome to Hall 17.2, booth F33-36, G13-16

Hall 18.2, booth B32-33,C16-17

We are waiting for you

Shinhoo products pre-empt the prophet
GPA-H series heat pump system dedicated pump, seamless switching between cooling and heating.
(1) Integrate multiple control methods (PWM, Lin, 0-10V, etc.);
(2) With multiple functions (power feedback, speed feedback, flow feedback, head feedback, etc.);
(3) Various styles (MAX file + PWM file, multi-file + PWM file, PWM file);
(4) Full coverage of performance (flow 0-1Om³/h, head 4-17m).

The Difference between Booster Pump and Circulating Pump

As the name implies, booster pumps and circulating pumps have different performances . They have their own characteristics for obvious differences in terms of installation location, scope of application, operation and control.



From the perspective of installation location, the booster pump is generally installed on the inlet pipe; the circulating pump needs to be installed on the return pipe.



From the point of view of the scope of application, booster pumps are generally used in central heating systems, where the water pressure is small due to the small drop with solar energy, and the water pressure of the water heater is small, and the pressure needs to be boosted; the circulating pump is mainly for self-heating users, or the heating system of large and medium-sized households circulates, and the floor heating hot water is circulated.



From the perspective of boosting strength, booster pumps mainly solve the problem of lower water pressure, which is a type of pump with lower pressure; and the circulating pump has a higher pressure than the booster pump, which can drive the circulation of the entire heating system.



From the perspective of product operation, the booster pump is mostly automatically controlled; the circulating pump is mostly manually controlled.

 

Shinhoo, a company specializing in the manufacturing of canned pumps, launched a new upgrade of cooling and heating dual-purpose high efficiency circulation pumps (GPA-H series) --- 11H, 17H, which can be easily installed and operated.


11H, 17H are equipped with Self Adapting mode AUTO(default setting). Pump runs once the power is connected and adapts its perfomance according to the actual system needs. At the same time, the exterior of the electric pump has a digital pulse-width modulation (PWM) function to control the motor speed to meet the different flow requirement of the various system. 

The running noise of the electric pump is as low as 42dB(A), bringing a new comfortable experience to your family. The electric pump comes with over-voltage and over-current protection to prevent the danger of burning out during use. The minimum energy consumption can reach 5W, and the EEI≤0.20-Part3 meets the requirements of the latest ERP2015, allowing you to use it with a low-carbon lifestyle and feel at ease.